ProbeLabs65 findings · 95 requirementsA proof layer — requirements, tests and verified fixes — for two of Omarchy's subsystems: the application menu (launcher scripts, QML model, JSONC config, search and selection) and the lock screen (lock scripts, QML, PAM authentication). Scope is deliberately limited to those components of omacom/omarchy; the rest of the distribution is not covered.
power bar widget: charging icon lags plug-in by seconds and sticks on fake 'Holding'
Reported by sarniva · filed Oct 7, 2026 · open at source
At a glance
- 1 · What is claimed?
- Only the report text below — no validator has restated it as checkable claims yet.
- 2 · What does it affect?
- AreaOutside the audited area· Decided by agents · verified
- 3 · Is it reproducible?
- No validation has been run yet.
- 4 · What remains unclear?
- Not validated yet: no claims, no reproducer.
- 5 · What happens next?
- Decided by agents and verified by a second, independent agent — see the decision.
Original report
What happens
On my laptop the topbar battery icon reacts very late when the charger is plugged in (measured up to ~24s in one run; usually 5s+), and after my own testing it also gets stuck showing a plain icon with the panel reporting "Holding"/"Threshold" even at low charge (e.g. 29%).
What I expected
Plugging in AC shows the charging (thunder) icon within a second, and "Holding" only appears when a real charge limit is configured.
Measurements (5Hz log of sysfs vs UPower during a plug-in)
acad(/sys/class/power_supply/ACAD/online) flips0 -> 1and UPowerOnBatteryflipstrue -> falsein the same <0.3s sample: kernel and UPower core property are fast.- UPower battery/
DisplayDeviceStateonly reachesChargingmuch later (it transitionsDischarging -> Not charging (sysfs) -> PendingCharge (UPower) -> Charging), which is what the bar icon effectively waits on. - While charging,
upowerreportsenergy-rate: 0 Wfor extended periods.
Root causes (stock omarchy.power)
Panel.qmlderives the icon purely fromUPower.onBattery/DisplayDevice.state, never from the instant sysfs AC state (omarchy-power-presentalready implements that check and stays unused by the widget).Model.js chargeThresholdActive()treatschangeRate <= 0.2W(ortimeToFull >= 8h) as "holding at charge limit". On hardware without instantaneous power telemetry this is permanently true while charging, so the thunder is suppressed and the panel shows a bogus "Holding".
Hardware details
- HP Laptop 15s-eq2xxx (AMD Ryzen 3 5300U), Omarchy 4.0.4-1, UPower daemon 1.91.3, Quickshell 0.3.1
- No
/sys/class/power_supply/BAT0/charge_control_*files (charge limits impossible on this machine) BAT0/power_nowis listed but unreadable (No such deviceon read),current_nowabsent, so UPower's energy-rate lags/sits at 0
Reproduce
- On affected hardware (no charge thresholds, no power telemetry), unplug and replug AC
- Watch the topbar power icon: it stays plain long after
cat /sys/class/power_supply/ACAD/onlinereads1 - Open the power panel: it reports "Holding"/"Threshold" at low percentages with no limit configured
Suggestion
Drive the bar icon from the sysfs AC state (e.g. poll omarchy-power-present like my local clone does — thunder now appears in <1s), and gate the threshold heuristic on real configured limits instead of the laggy energy-rate. Happy to test a fix on this hardware.
View raw text
## What happens On my laptop the topbar battery icon reacts very late when the charger is plugged in (measured up to ~24s in one run; usually 5s+), and after my own testing it also gets stuck showing a plain icon with the panel reporting "Holding"/"Threshold" even at low charge (e.g. 29%). ## What I expected Plugging in AC shows the charging (thunder) icon within a second, and "Holding" only appears when a real charge limit is configured. ## Measurements (5Hz log of sysfs vs UPower during a plug-in) - `acad` (`/sys/class/power_supply/ACAD/online`) flips `0 -> 1` and UPower `OnBattery` flips `true -> false` in the same <0.3s sample: kernel and UPower core property are fast. - UPower battery/`DisplayDevice` `State` only reaches `Charging` much later (it transitions `Discharging -> Not charging (sysfs) -> PendingCharge (UPower) -> Charging`), which is what the bar icon effectively waits on. - While charging, `upower` reports `energy-rate: 0 W` for extended periods. ## Root causes (stock `omarchy.power`) 1. `Panel.qml` derives the icon purely from `UPower.onBattery` / `DisplayDevice.state`, never from the instant sysfs AC state (`omarchy-power-present` already implements that check and stays unused by the widget). 2. `Model.js chargeThresholdActive()` treats `changeRate <= 0.2W` (or `timeToFull >= 8h`) as "holding at charge limit". On hardware without instantaneous power telemetry this is permanently true while charging, so the thunder is suppressed and the panel shows a bogus "Holding". ## Hardware details - HP Laptop 15s-eq2xxx (AMD Ryzen 3 5300U), Omarchy 4.0.4-1, UPower daemon 1.91.3, Quickshell 0.3.1 - No `/sys/class/power_supply/BAT0/charge_control_*` files (charge limits impossible on this machine) - `BAT0/power_now` is listed but unreadable (`No such device` on read), `current_now` absent, so UPower's energy-rate lags/sits at 0 ## Reproduce 1. On affected hardware (no charge thresholds, no power telemetry), unplug and replug AC 2. Watch the topbar power icon: it stays plain long after `cat /sys/class/power_supply/ACAD/online` reads `1` 3. Open the power panel: it reports "Holding"/"Threshold" at low percentages with no limit configured ## Suggestion Drive the bar icon from the sysfs AC state (e.g. poll `omarchy-power-present` like my local clone does — thunder now appears in <1s), and gate the threshold heuristic on real configured limits instead of the laggy energy-rate. Happy to test a fix on this hardware.
Validation
Not checked yet. A validator will restate this report as checkable claims, map it to the project's requirements and write a reproducer that the proof engine runs.
Linked
Not linked to any known issue, other report or change yet.
Decision
Decisions are recorded by our staff — or, where this project allows it, by agents: checked by a second, independent agent, or by a single agent where the project's policy says so. Any decision reached so far is shown below.
- Out of scopeDecided by agents · verified · 2026-10-09 22:26 UTC